Newster NW50

Company name :

Newster

Product name:

Newster NW50

Price :

0

Details:


Newster NW50

The Newster NW50 machine was designed for use in large hospitals and by waste disposers. The design allows the system to work for several shifts. Running the motor via the driver allows to leverage the power of the engine. The water recycling system guarantees maximum effectiveness, safety and work continuity besides a further reduction of running costs. A specially designed system for the discharge of the material allows the operator to manage the treated waste easily. The system can be equipped with an automatic loader.

 

 NEWSTER® NW50 - Sterilizer for potentially infectious healthcare waste
 

 Technical Specifications
 

 Sterilization method

 Unpressurized moist waste

 Heating method

 by impact and friction of the waste

 Processing potential

 75-90 kg/h1
 840 lt/h

 External aspect of treated waste

 Homogenious small-sized granules

 Final weight of treated waste

 70-75% of initial weight

 Final volume of  treated waste

 20-25% of initial volume

 Sterilization vessel volume                              

 Roughly 460 liters
 Ø= 806 mm, H= 965mm

 Overall control system

 Programmable logic controller (PLC)

 Temperature measurement

 By variable-resistance sensors

 Cycle recording

 Time-temperature flow recording

 Final cooling

 Roughly 95°C through H2O evaporation

 Dust abatement

 in humid environment

 Vessel lid closure

 Manual, mechanical blocking and double safety device

 Safety devices

 Mechanical blocking system of sterilization vessel lid ; Power  supply to main engine is cut off in case of lid blocking failure.  Low voltage command and control panel with  automatic  power cut-off if panels are open ; electrical resistor heating  system to be used in case of emergency stop

 Rotating blades and fixed contrablades

 Made of special metal alloys

 H2O Consumption

 Roughly 50 lt/day with water recycling system

 Water discharge

 40 mm diameter sewer pipe equipped with a trap

 Power consumption

 overall max 90 kW


 Size and weight
 

 Sterilizer

 250 x 120 x 210 cm

 Filter Group

 80 x 35 x 150 cm

 Electric board

 75 x 45 x 110 cm

 Electric board

 80 x 60 x 180 cm

 Total weight

 2670 kg


1 Depending on the percentage of humidity and density

The above specifications are intended for information purposes only and may be subject to change without prior notice.

 

 

The machine was designed for use in large hospitals and by waste disposers

 

The heavy-duty and resistant design allows the system to work for several shifts

 

Running the motor via the driver allows to leverage the power of the engine

 

The water recycling system guarantees maximum effectiveness, safety and work continuity besides a further reduction of running costs

 

A specially designed system for the discharge of the material allows the operator to manage the treated waste easily

 

The system can be equipped with an automatic loader